Cluster Climate Envelope
Design Dry Bulb
44°C
Design Wet Bulb
28.4°C
Dust & Particulate Severity
HighPrimary Target Industries
- Heavy Steel Tube Mills & Cold Rolling Operations
- Chemical Formulations, Inks & Polymer Pigments
- Packaging Machinery & Corrugated Box Mills
Engineering Recommendation
Thermal Stress Analysis
Abrasive carbon dust and chemical vapours clogging open filter fans, accelerating dielectric breakdown across LT panel busbars and CNC automation modules.
Recommended Air Washer Architecture
Direct Evaporative Air Washer with Multi-Bank Pre-Filters & PVC Drift Eliminators
Recommended Panel Enclosure Protection
IP55 / Powder-Coated MS Enclosure with R-134a Eco-Friendly Refrigerant
Dispatch & Factory Spec
Deploy Factory Evaporative Air Washer Unit in Sahibabad & Kavi Nagar Industrial Area
Submit panel enclosure measurements, CFM static pressure targets, or single-line diagrams (SLD). Our engineering desk provides validated thermal heat load sizing and line-item BOQs within 3 hours.