Cluster Climate Envelope
Design Dry Bulb
42°C
Design Wet Bulb
30.5°C
Dust & Particulate Severity
MediumPrimary Target Industries
- Automotive OEM Assembly Lines & EV Battery Plants
- Consumer Electronics & Mobile Hardware SMT Cleanrooms
- Heavy Precision Auto-Component Toolrooms & Press Shops
Engineering Recommendation
Thermal Stress Analysis
Sustained high coastal relative humidity (RH > 80%) combined with high wet-bulb peaks, causing severe condensation inside enclosures and dielectric track degradation on high-speed robotic controllers.
Recommended Air Washer Architecture
High-CFM Double-Skin Air Washer with Low-Velocity Mist Eliminator Bank & UV Water Disinfection
Recommended Panel Enclosure Protection
IP55 Panel AC with Built-In Active Condensate Evaporator & Hydrophilic Blue Fin Coils
Dispatch & Factory Spec
Deploy Factory Evaporative Air Washer Unit in Sriperumbudur-Oragadam Industrial Corridor (SIPCOT)
Submit panel enclosure measurements, CFM static pressure targets, or single-line diagrams (SLD). Our engineering desk provides validated thermal heat load sizing and line-item BOQs within 3 hours.