Centralized motor drive management designed for continuous-duty industrial plants, pump rooms, heavy air systems, and automated production corridors. Built with verified Type-2 short-circuit coordination, microprocessor-based motor protection relays (MPR), and dedicated isolated vertical cable chambers.

From heavy mechanical pump houses to multi-fan ventilation arrays, our MCC panels ensure maximum electrical life.
Engineered with motor circuit breakers (MPCB), heavy-duty contactors, and thermal-electronic overloads tested to withstand peak short-circuit events without contact melting or permanent weld damage.
Eliminates miles of control wiring by routing operating current, thermal overload curves, running hours, and start/stop commands over RS485 Modbus RTU, Profibus, or BACnet IP directly to the central control room.
Drawout cassette units feature reliable mechanical interlocks, distinct Test/Service/Disconnected positions, and self-aligning power stabs for safe maintenance during live operation.
Manufactured and inspected strictly in compliance with IS 8623, IEC 61439-1 & 2, and IEC 60947-4-1 standards.
| Engineering Parameter | Adhunik Powertech Specification |
|---|---|
| Rated Operational Voltage (Ue) | 415V AC ± 10%, 3-Phase, 3-Wire / 4-Wire, 50 Hz |
| Rated Insulation & Impulse Voltage | 1000V AC Insulation / 8kV Peak Impulse Withstand |
| Main Horizontal Busbar Rating | Up to 3200A Continuous Rating (Electrolytic Cu / E91E Al) |
| Vertical Dropper Busbars | Isolated, Fully Shrouded Vertical Busbar Alley (Up to 1000A) |
| Short-Circuit Fault Capacity | 50kA / 65kA rms for 1.0 Second (CPRI Type-Tested) |
| Short-Circuit Coordination | Type-2 Coordination Verified (Zero Contactor Welding) |
| Internal Separation Class | Form 3b / Form 4b (IS 8623 / IEC 61439-1 & 2 Compliant) |
| Module Execution Types | Fully Compartmentalized Fixed Type & Fully Drawout Cassette Type |
| Starter Feeder Configurations | Direct-On-Line (DOL), Automatic Star-Delta, Soft-Starters & VFDs |
| Motor Protection Units | Microprocessor MPR (Thermal Model, Jam, Stall, Earth Fault, Phase Loss) |
| Intelligent IMCC Protocol Options | Modbus RTU (RS485), Profibus-DP, Ethernet/IP, Profinet & BACnet |
| Enclosure Construction & Finish | 1.6mm / 2.0mm CRCA Sheet Metal, 7-Tank Treated, 60–80μm RAL 7032/7035 |
| Ingress Protection (IP Class) | IP42 (Indoor Natural) / IP54 / IP55 (Continuous CNC PU Foam Gasketing) |
Every motor feeder is sized for thermal stability, optimal torque, and reduced utility power dips.
Equipped with MPCB and heavy-duty contactors for high starting torque loads such as small utility pumps, auxiliary fans, and compressors.
Transition timer controlled with mechanical and electrical interlocking contactors to cut inrush starting current to one-third of normal values.
Thyristor-controlled voltage ramp starter with integrated bypass contactor, eliminating hydraulic water hammer in long pump pipelines.
Integrated variable frequency drives for continuous closed-loop speed modulation, line chokes, and specialized enclosure panel air conditioning.
Submit your motor load list, feeder ratings, or Single-Line Diagram (SLD). Our senior engineering desk will verify Type-2 coordination, drawer sizes, and provide a comprehensive proposal.
Our engineering team in Gurugram / Delhi NCR reviews electrical schedules and delivers complete GA drawings and offers within 24–48 hours.